Purified water system
WEMAC customized optimization design according to the raw water quality report,effluent quality requirements and the actual needs of customers, and customer can also choose the standardized design from WEMAC. The output water quality can meet the requirements of Chinese Pharmacopoeia(CP2020), United States Pharmacopoeia (USP43) and European Pharmacopoeia (EP10) for purified water or high purity water according to different system configurations.
1. Modular design, compact structure, beautiful layout, convenient operation and maintenance.
2. The double softeners in pretreatment unit can realize series operation and alternate regeneration by using valve group. Each water softener has 100% water supply capacity. The whole process of softener operation, backwashing, salt absorption, regeneration and washing is fully automatic and programmed.
3.Frequency conversion control is adopted for raw water pump, RO1 and RO2 high-pressure pumps, which can not only realize different pressure control of filter and softener under various operating conditions, but also realize low-speed and small circulation of produced water in system standby time, greatly reducing the probability of microbial breeding and effectively saving energy.
4. The terminal water production of the system adopts a dual-channel water supply and single-channel circulation mode, that is, when the product water is qualified, it enters the purified water storage tank through two pipelines. While when the product water is unqualified, the product water circulates through the two pipelines and then flows back to the middle water storage tank. When the purified water storage tank is full, it will automatically switch to the circulation pipeline operation, which effectively avoids the existence of empty pipes and ensures that there is no dead water.
5. The middle water storage tank is used as the buffer tank to realize online cleaning, eliminating the separate cleaning system. The system can choose thermal disinfection RO membrane and thermal disinfection EDI to realize online hot water sanitization of the whole system.
6. As far as possible, use stainless steel pipes to directly stretch the elbow to avoid welding seam. Welding parts of pipelines and accessories should be automatically welded with argon protection(single-side welding and double-side forming process) to ensure welding quality, and electrochemical polishing after welding.
7. Provide endoscopy photos, solder joint diagram, pressure test and pickling passivation report, system design documents and other verification data.
8. The control system adopts HMI+PLC fully automatic control, and the operation interface is simple. Various communication modes are available. Control system authority levels: at least three levels of authority can be set.
9. Online monitoring of parameters such as conductivity, temperature and flow. The recorder can choose a paperless recorder or a paper recorder to record and print key parameters.
10. The control system can be optionally equipped with electronic signatures and electronic records, so that the system control has an audit trail function, and meets the requirements of GAMP 5 and 21 CFR PART 11.
Name | Description | |||||
Pre-treatment system | Pretreatment process contains traditional processes, such as Feed water storage tank,Heat exchanger heating device,Mechanical filtrater, activated carbon filtrater, softener,Precision Filter, dosing device, as well as ultra-filtration, residual chlorine removal UV, micro-filtration, etc. | |||||
RO2 system | Based on demands of raw water quality conditions and terminal water,RO2 can be used as terminal processing of PW generation system. If alkalinity of raw water is on the high side, degassing device can be chosen. The water quality conforms to requirements of Chinese pharmacopoeia, European pharmacopoeia and United States pharmacopoeia. |
|||||
RO1+EDI system | Based on demands of raw water quality conditions and terminal water, RO1 +EDI can be used as terminal processing of PW generation system. Quality of water produced by RO1 + EDI is stable, only slightly affected by fluctuation of raw water quality. The water quality conforms to requirements of Chinese pharmacopoeia, European pharmacopoeia and United States pharmacopoeia. |
|||||
RO2+EDI system | Adopting RO2+EDI system as terminal processing of PW generation system, produced water will only be slightly affected by fluctuation of raw water quality. Quality of produced water is stable and highly above requirements of Pharmacopoeia. | |||||
Residual chlorine removal UV system | Using residual chlorine removal UV system in pretreatment, instead of activated carbon filter. At the same time of efficient removal of residual chlorine, system can completely inactivate raw water microorganism, ensuring safety of microorganism from the source and improving quality of supply water. It supports online UV intensity monitoring and dosage display, which can accurately predict dechlorination effect and completely avoid troubles from activated carbon filter. |
RELATED PRODUCTS
ONLINE INQUIRY
Rigorous testing
ust the quality of products
24/7 Online services
High quality after-sales service
On time delivery
Strong production capacity, sufficient stock
Quality qualification
Good quality price is lower
CONTACT US
Shandong Eagle Machinery Co.,Ltd
Address: Block B, Headquarters Base ABP, No.2600,
Zhuangjian Road.Weifang, Shandong, P.R.C.
Tel: +86-536-8800237
Email: Hrs@sdwemac.com
WhatsApp:
Naomi: 0086-15315252862
Crystal Zhao: 0086-15053106839
Copyright © Shandong Eagle Machinery Co.,Ltd. Powered by www.300.cn 鲁ICP备19023047号-4